- User Manual Template
- Micronta Multimeter User Manual Guide
- Micronta Multimeter User Manual Diagram
- Micronta 22 167 Manual
Micronta Multimeter Service Manual with schemaatic. EMBED (for wordpress.com hosted blogs and archive.org item tags).
The Micronta line of electronic multimeters, sold for decades through Radio Shack stores, offered a wide range of entry and intermediate-level models. The model 22-167 was a typical example of an intermediate-level Micronta digital multimeter, providing measurement of current, voltage and resistance with 3 3/4 digits of precision.
Analog and Digital
The many models of Micronta multimeters generally fall under two main types: analog and digital. An analog multimeter uses a mechanical needle movement on a dial to display voltage, current and resistance measurements; digital models use a modern liquid crystal display; some offer additional measurement modes such as continuity, diode check and capacitance. Most digital models automatically find the correct measurement range and polarity.
Setup and Power-On
User Manual Template
- Press the power button on the meter.
- Insert the red meter probe into the jack marked VΩ. Insert the black probe into the COM jack.
Tip
The meter has an automatic battery check function. The meter displays -[+ / -] when the battery is marginal. Replace the meter’s internal battery if the display does not turn on or you see the -[+ / -] symbol.
DC Volts
Turn the meter’s selector knob so it points to the --V function, used for measuring the voltage of direct current.
Touch the metal tip of the red probe to the battery’s positive terminal. Touch the tip of the black probe to the negative terminal.
Read the meter display. You should see a measurement of about 9 volts; the exact figure depends on the condition of the battery.
Press the Data-H button to hold the data in the meter. Disconnect the probes from the battery. Observe that the display retains the voltage reading even though the probes no longer touch the battery. Press the Data-H button again and observe that the display returns to reading of zero volts.
Disconnect the probes from the battery.
Resistance
Turn the function selector switch so it points to the Ω function, indicating resistance measurement in ohms. Indian author books free download.
Touch one probe tip to one lead of the resistor. Touch the other probe tip to the resistor’s unconnected lead.
Read the meter display. You should see a measurement of about 1,000 ohms, depending on the resistor’s actual value. For example, you may see a reading of 900 ohms for a 1K resistor whose tolerance is 10 percent.
Disconnect the probes from the resistor.
DC Current
Turn the function selector so it points to the 32/320 mA setting. This setting measures DC current in the milliamp range.
West australia driver licence. Connect one of the resistor leads to the positive terminal on the battery.
Touch the metal tip of the red probe to the resistor’s free lead. Touch the tip of the black probe to the battery’s negative terminal.
Read the meter display. You should see a measurement of about 9 milliamps, depending on the actual battery voltage and resistor value.
Micronta Multimeter User Manual Guide
Disconnect the probes from the resistor and battery. Disconnect the resistor from the battery.
Initial d games free. Flasharcade.com offers Initial D Drift Game. Also many more games like Flash games, Online Arcade games, Shooting games, Puzzle games, Fun games, Adventure games, Action games, Sports games and Many more Free online games. Initial D: Drift Stage. Add this game to your web page! Open embedded menu Hey, join us on the Y8 Discord chat! Find discussions related to Y8's top games. Find discussions related to Y8's top games. Don’t hesitate to join the Y8 Discord! Go to Y8 Discord Hide.
Micronta Multimeter User Manual Diagram
Warning
Micronta 22 167 Manual
Do not measure DC currents for voltages greater than 750V with this meter.